Overview: Overflows drain water from display tank to sump. Multiple designs with different noise and reliability tradeoffs. Durso standpipe: single vertical pipe and air vent at top.
Durso standpipe: Single vertical pipe + air vent at top. Quiet enough for most. Hardware-store-friendly.
Herbie: Two pipes - one full (primary), one open (emergency). Quiet during normal operation. Emergency relief when primary clogs.
BeanAnimal: Three pipes - one full (siphon), one open (emergency), one secondary (atmospheric). Whisper-silent operation. Most reliable but more expensive + complex.
Hang-on-back overflow: Boxes hanging on back of tank without drilled holes. Used when display can't be drilled. Less reliable than drilled overflows.
Drilled overflow: Through-glass plumbing. Most reliable. Requires drilling tank (most modern tanks come pre-drilled).
Sizing: 1" or larger drain lines for primary flow. 3/4" return line. Match flow capacity to sump pump.
Common pitfalls: Undersized drain causing overflow at top. Air entrainment causing noise. Plumbing glue gone bad causing leaks.
Where to learn more: Browse filtration types.